Skip to main content
VEGF-trap fusion protein

Aflibercept Eylea®

The SHIKARI® Aflibercept portfolio provides one quantitative free-drug assay plus quantitative and qualitative anti-aflibercept antibody assays for human serum or plasma.

3
SHIKARI® Kits
96
Tests per kit
2
Analytical Domains
RUO
Research Use Only
Official Aflibercept product-page opening visual
TRACE & CATCH · AFLIBERCEPT
Scientific Background

Why Aflibercept is relevant to biological-drug monitoring research

Aflibercept has clinically important target biology, indication-specific dosing and measurable systemic exposure, making drug concentration and immunogenicity relevant research variables. Scientific source ↗ · EMA source ↗

Mechanism

Molecular Target & Structure

Aflibercept is a recombinant VEGF-receptor fusion protein that acts as a soluble decoy receptor for VEGF-A and placental growth factor (PlGF). Source ↗

Indications

Approved Indications

EMA-authorised ophthalmic uses include neovascular age-related macular degeneration and other retinal disorders driven by pathological vascular leakage or neovascularisation, including diabetic macular oedema and retinal-vein-occlusion-associated macular oedema. EMA source ↗

Regulatory PK Context

Systemic Exposure After Intravitreal Dosing

Systemic free-aflibercept concentrations after intravitreal dosing are very low and should not be interpreted as ocular therapeutic targets:

Wet AMD · systemic Cmax~0.02 µg/mL
RVO · systemic Cmax~0.05 µg/mL
DME · systemic Cmax~0.03 µg/mL

Regulatory exposure values are regimen- and population-specific and are not therapeutic targets. Values vary with dose, timing, formulation and study population. This page is for RUO product information and does not provide clinical guidance.

SHIKARI® Kit Portfolio

Three verified Aflibercept research assays

SHIKARI® Q-AF kit, REF AFL-FD-EYL
Drug Levels Kit
SHIKARI® Q-AF
Aflibercept (Eylea®) ELISA
REF: AFL-FD-EYL

Ligand-binding ELISA for quantitative analysis of free aflibercept in human serum or plasma.

Representative Standard Curve
SHIKARI® Q-AF representative standard curve for illustrative purposes only
96Tests/kit
2–8°CStorage
10–30°CShipment
Ligand-binding assaySerum / Plasma1-year shelf life
SHIKARI® S-ATAF kit, REF AFL-QNS-EYL
Quantitative ADA Kit
SHIKARI® S-ATAF
Quantitative Antibodies to Aflibercept ELISA
REF: AFL-QNS-EYL

Quantitative ELISA for anti-aflibercept antibodies in human serum or plasma, including the assay-specific confirmation procedure.

Representative Standard Curve
SHIKARI® S-ATAF representative standard curve for illustrative purposes only
96Tests/kit
2–8°CStorage
10–30°CShipment
Confirmation procedureSerum / Plasma1-year shelf life
SHIKARI® S-ATAF kit, REF AFL-QLS-EYL
Qualitative ADA Kit
SHIKARI® S-ATAF
Qualitative Antibodies to Aflibercept ELISA
REF: AFL-QLS-EYL

Qualitative ELISA for positive or negative assessment of anti-aflibercept antibodies in human serum or plasma according to assay-specific cut-off interpretation.

96Tests/kit
2–8°CStorage
10–30°CShipment
Qualitative ADASerum / Plasma1-year shelf life
Technical Reference

Verified Specifications at a Glance

KitREFModeAnalyteSampleVolumeTimeAnalytical outputTestsShelf lifeStorageShipping
SHIKARI® Q-AFAFL-FD-EYLQuantitativeFree afliberceptHuman serum / plasma5 µL105 minLOD 10; LOQ 30 ng/mL961 year2–8°C10–30°C
SHIKARI® S-ATAFAFL-QNS-EYLQuantitativeAnti-aflibercept antibodiesHuman serum / plasma50 µL110 minLOD 1; LOQ 3 ng/mL961 year2–8°C10–30°C
SHIKARI® S-ATAFAFL-QLS-EYLQualitativeAnti-aflibercept antibodiesHuman serum / plasma20 µL140 minPositive; negative961 year2–8°C10–30°C

Analytical specifications are summarised from the current controlled IFUs and exact official product records. Standard curves are official illustrative product images and must not be used for sample quantification. Follow the link on each assay card for the corresponding product record on matriksbiotek.com.

Kit Selection Guide

Match the assay to the research question

01
Quantify free aflibercept
Use AFL-FD-EYL for quantitative free-drug measurement.
02
Quantify anti-aflibercept antibodies
Use AFL-QNS-EYL for quantitative ADA research with its confirmation procedure.
03
Screen qualitatively for ADA
Use AFL-QLS-EYL for a positive or negative anti-aflibercept antibody result.
04
Study exposure and immunogenicity together
Pair AFL-FD-EYL with the ADA format selected by the research protocol.
Scientific Literature

Aflibercept Literature and Product-Use Records

Technical Support & Quotations

Planning a Aflibercept research study?

Matrix Biotek can help identify the appropriate Aflibercept assay and prepare regional quotation and delivery information.

Quotation Request

Review your quote list

Your quotation request is sent directly to Matrix Biotek. A confirmation copy will be sent to your institutional email. No payment is taken online. Current regional pricing, availability and delivery information will be provided in the quotation.

Technical Support